Transient Voltage Surge Suppressor
240 / 120v - Single Phase |
 |
 |
|
| (ELE) LW2XXC |
|
- Description
- Surge Blox
- Alarm Circuit
Transient Voltage Surge Suppressor. 240 / 120v, single-phase.
Nema 4X (clear plastic hermetically sealed lid), fiberglass cabinet. A dedicated two-pole
disconnect or breaker, (100 amp, 250 volt {preferred}, or 60 amp, 250 volt) is
required for this suppressor (non-fused). Weight = 12 pounds. Absolutely
the best surge suppressor money can buy for house or business!!
"C" Surge Blox™
It has two very high end Surge Blox 200 Suppressor
Modules @ 3,000 Joules per phase. (200,000 Peak Amps, 220 Volt Clamp). The
design utilizes silicon avalanche diodes (SADs) or metal oxide varistors (MOVs)
in easy-to-repair and upgrade modular designs. They
have a red/green self checking LED circuit and companion alarm
panel with Form C contacts to activate an alarm in the event
of suppression failure. AC Data Systems, manufacturer of
the Surge Blox 200 states this assemblage offers redundant
protection to prevent damage from repetitive voltage spikes
generated by recurrent outages or by the turning on and off
of other mechanical and electrical equipment as well as from
oscillatory, decaying transients generated by lightning.
Alarm Circuit Assembly
Patented PC board traces are monitored by the alarm assembly to alert you of individual
MOV loss and to provide reliable high-surge current capacity and low let-through
voltage MOV protection. One by one, individually fused and alarmed MOVs are removed
from the suppression system when degraded and damaged. The specs on the alarm
circuit assembly are as follows:
• Voltage: 120 vac RMS
• Frequency: 50/60 Hz
• Operating Temperature: -20 to 80º
|
|
|
|
|
| $695 each - $595 (3+), $550 (12+), $495 (24+) |
|
|
|
|
|
AC Line Protector
20 amp / 120 vac |
 |
|
|
(RMO) 587B201
General Semiconductor Industries AC line protector. Nano-second response time. 20 amp, 120 vac. 3-1/2" c-c mounting holes. 3" x 3" x 1-1/2" high. |
|
|
GE Thyrite Surge Arrestor
650 vac Three Phase / 630 vdc |
 |
|
(RMO) 9L15BC003
GE Thyrite Surge/Lighting Arrestor. 0-650v AC Three Phase line protector. Metal Cylinder 3"dia. x 5 1/8" with 1" top mount. |
|
|
|
Transient Voltage Suppressor |
 |
|
(RMO) 15KP36A
EIC transient voltage suppressor. EIC P/N: 15KP36A.
• 36v reverse standoff
• 10 µA maximum reverse leakage
• 40v breakdown voltage @ 5 ma
• 5% tolerance
• 59.7v maximum clamping voltage
• 251 amp maximum peak pulse current
• 41º maximum voltage temperature
• Uni-directional
• Dimensions: 1" x 7/16" x 11/16"H
|
|
|
Suppression Capacitor
1 µF / 250 vac / 630 vdc |
 |
|
(CFPA) 001R000FBDF
Roederstein / Vishay suppression capacitor. Metalized polyester. Axial. Mfg. P/N: F1773-510-2000.
• 1 µF, 250 vac, 630 vdc
• 10% tolerance
• 0.70" diameter x 1.25" long
• 0.04" (18 gauge) leads
|
|
|
|
$3 each - $2.50 (50+), $2 (250+), $1.75 (500+),
$1.50 (1,000+), $1 (10,000+), 78¢ (25,000+) |
|
|
|
|
|
|
Surge Eliminator
120v / 5 amps |
 |
(RMO) 001-00-0990
L.E.A. Dynatech surge elminator. 120v, 5 amps. 3 wire: hot, neutral, ground. 4" x 2-3/4" x 15/16"H. Mfg. P/N: 18038. |
|
|
Lambda Overvoltage Protector
6 - 20 vdc |
 |
|
(PS) LMOV-2
Lambda overvoltage protection. Range 6 - 20 vdc, adjustable. 2 mounting holes, 3" c-c. Attaches to rear of many different Lambda supplies. 3-3/8"L x 1/2"W x 1"H. |
|
| $12 each - $10 (6+), $9 (25+) |
|
|
|
|
|
|
Lambda Overvoltage Protection
3 - 8 vdc |
 |
(PS) LMOV-7
Lambda overvoltage protection. 3 - 8 vdc.
Can withstand 35 amps fault current for 1 minute or 80 amps fault current for 1 second.
4" x 2-3/4" x 1-3/4"H. Includes
manual. |
|
|
Siemens SVP Gas Tubes
Striking Voltage: 230 vdc |
 |
(RMO) L2-A230
Supreme protection against spikes and surges. 20kv nominal breakdown.
7/16" diameter x 2" long. 73Pm 147, ESsich36d. |
|
| |
|
| $15 each - $13 (10+),
$10 (100+) |
|
|
|
|
Overvoltage Protection
Module
|
 |
|
(SIC) KRO6-5
C.E.L. overvoltage protection module. 1-1/8" x 1-1/8" x 1-1/2" |
|
|
Thyrite Resistor
Surge Arrester
200 vdc |
 |
(RMO) 102B4208P1
General Electric thyrite resistor, surge arrester. 200 vdc. We don't know the current this will handle but it must be many 100s of amps. 5" x 7-1/2" x 8"H. Mfg. P/N: 9RVX6D70.
NSN: 5920-00-904-8588. |
|
|
|
|
Gas Discharge Tube |
 |
| (RMO) CG3-3.0L |
|
- Description
- Specifications
Gas discharge tube. Made by CPC. 4,000 available.
• DC Breakdown = 3kv (2.4kv - 3.6kv) with leads.
• 1010 ohm Insul. res.
• 3/8"D x 3/8"L body
• 1"L leads
|
|
|
|
Gas Discharge Tube |
 |
| (RMO) 3YVJ-300J1 |
|
- Description
- Specifications
Sankosha 3 terminal gas discharge tubes
for spike protection of Telco equipment. The clamp voltage
of 300 volts is perfect for Telco providing circuit protection
for apparatus and personnel, from high transient voltages caused by lightning,
contact with power line or electromagnetic induction.
• DC Spark over voltage
250 - 350 volts
• Impulse Spark over voltage 900 volts max
• AC discharge current 10 amps 50/60 Hz
• Impulse discharge current 10 amps 8/20µs
• Transverse voltage difference time 200 ns
• Insulation resistamce 1000M ohm min 100 vdc
• Capacity @ 1 MHz, 3 pF max
|
|
|
| $4 each - $3.50 (25+), $2.75 (100+), $2.25 (250+) |
|
|
|
| $2 -
$1.50 (10+), $1.25 (100+), $1 (250+), 85¢ (1k+) |
|
|
|
|
|
Gas Gap Arrestor
For Sensitive Electronic Equipment |
 |
(RMO) KAS02
200 vdc. |
|
|
Gas Gap Arrestor
For Sensitive Electronic Equipment |
 |
(RMO) TO8-230B
230 vdc. |
|
| $2 each
- $1.50 (6+), $1 (25+) |
|
|
|
|
| $2 each
- $1.50 (6+), $1 (25+) |
| |
|
|
|
SVP Gas Tube
400 vdc Spark Over / 800v Impulse Spark Over |
 |
(RMO) T61-C350
Siemens SVP gas tube. 3 leg. 400 vdc spark over, 800v impulse spark over. Arc voltage @ 1 amp = 35v. 20 amp single impulse discharge current. 11.5mm x 8.3mm. |
|
|
MSP Gas Tube Surge Suppressor
350v |
 |
|
(RMO) 2029-35-BT1
Joslyn Electric MSP gas tube surge suppressor. 350v, ±20% - DC spark over voltage. 20 amps AC RMS. 20,000 amps surge. |
|
|
|
| $4 ea - $3.50 (6+), $3 (25+), $2.60 (100+), $2 (500+) |
|
|
|
|
|
| |
Varistor
360v / 14mm / 4500 amps |
|
| |
 | |
| |
(RMO) ERZ-C14DK361
Matsushita / Panasonic varistor for 230 vac applications. Varistors are protective devices that decrease in
resistance as voltage approaches cutoff point, in effect dissipating
the spike to ground. ZNR surge absorber. 360 volts, 14mm, 4500 amps. 1-3/8" long leads. 5/16" lead spacing. 0.663" diameter x 0.213". 19,000 pcs available!! |
|
|
| 35¢ each - 27¢ (100+), 20¢ (1,000+) |
|
|
|
|
|
Zinc Oxide Varistor
270 vac / 360 vdc |
 |
|
(RMO) D65Z0V271RA
MDC (Maida Development Company) zinc oxide varistor. Z271,
140ul. PC mount. 270 vac, 360 vdc, 325 joule. 10,000 amp peak, 1 pulse. 20mm diameter.
CSA / UL approved. Mfg.
P/N: D65Z0V271RA140. — 20,000 available!! |
|
|
Varistor
175 vac / 225 vdc |
 |
(RMO) V175LA10A
Harris varistor. 14mm. 175 vac / 225 vdc. 55 joules. Clamps at 247 volts. 4500 amps peak. |
|
| 75¢ - 50¢ (25+), 35¢ (100+), 25¢ (250+),
19¢ (1,000+) |
|
|
|
| 35¢ each - 27¢ (100+), 20¢ (1,000+) |
|
|
|
|
|
Varistors |
 |
(RMO) P6KE6.8A
6.8v, 57 amp peak. |
| 75¢ each - 55¢ (10+),
45¢ (50+) |
|
|
(RMO) P6KE7.5A
7.5 v, 53 amp peak. |
|
|
Varistors |
 |
(RMO) V68MA38
38 vac, 48 vdc, 0.26 joule. |
| 75¢ each - 55¢ (10+),
45¢ (50+) |
|
|
(RMO) V68MA3B
40 vac, 56 vdc, 0.3 joule. |
|
| 75¢ each - 55¢ (10+),
45¢ (50+) |
|
|
|
| 75¢ each - 55¢ (10+),
45¢ (50+) |
|
|
|
|
Varistors Listed |
| |
| Part Number |
Rating |
Joules |
Notes |
Price Each |
|
| (RMO) 125L52 |
125 vac |
52 joules |
- |
2.00 |
|
| (RMO) V130LA20 |
130 vac |
70 joules |
G.E. radial wire lead,
100 amp peak |
0.75
0.50 (10+)
0.40 (100+) |
|
| (RMO) V130LA20B |
130 vac, 175 vdc |
70 joules |
Spade lugs on leads |
2.00 |
|
| (RMO) 232259551316 |
130 vac, 170 vdc |
- |
17mm diameter, 50 amp surge |
0.75 |
|
| (RMO) VD13-0151 |
150 vac |
13 joules |
- |
1.00 |
|
| (RMO) V150LAX1295 |
150 vac |
45 joules |
- |
2.00 |
|
| (RMO) V175LA10A |
175 vac, 225 vdc |
55 joules |
14mm, clamps @ 247v,
4,500 amps peak |
0.35
0.27 (100+)
0.20 (1k+) |
|
| (RMO) V175LA20B |
175 vac, 225 vdc |
90 joules |
- |
1.00 |
|
| (RMO) VZD250 |
250 vac, 320 vdc |
190 joules |
24 mm, 6500 amp peak |
2.00 |
|
| (RMO) V275L20B |
275 vac, 365 vdc |
23 joules |
- |
1.00 |
|
| (RMO) V275L40 |
275 vac, 369 vdc |
140 joules |
Spade lugs |
2.00 |
|
| (RMO) V480LA80B |
480 vac, 640 vdc |
180 joules |
6500 amp surge |
0.75
0.60 (100+)
0.45 (1k+) |
|
| (RMO) S14K550 |
500 vac, 680 vdc |
- |
- |
2.00 |
|
| (RMO) VZD-510 |
510 vac, 670 vdc |
190 joule |
24 mm, 6500 amp peak |
2.00 |
|
|
|
|
|
Inrush
Current Limiter
7 amp |
 |
(RMO) SL155R007
Ametherm 7 amp inrush current limiter thermistor. 5 ohm. 50 joule, 120 / 240 vac. 9/16" diameter x 1/8" thick. 7/16" lead spacing. |
|
|
|
| $1 each - 85¢ (6+), 60¢ (100+) |
|
|
|
|
|
Inrush
Current Limiter
15 amp |
 |
(RMO) SL222R515
Ametherm surge limiter thermistor controls initial surge at turn on for several
seconds. 15 amp, 2.5 ohm, 22 mm. |
|
|
Inrush
Current Limiter
14 amp |
 |
(RMO) SL224R014
Ametherm surge limiter thermistor controls initial surge at turn on for several
seconds. Radial leads.
14 amp, 4 ohm, 22 mm. |
|
| $1.50 each
- $1.25 (6+), $1 (25+) |
|
|
|
|
|
|
|
Transient Voltage
Suppressor
26v - 500v Peak |
 |
(RMO) SA26A
• 30v
@ 1ma V Reverse Standoff
• ±1.50v tolerance
•
1µa @ 26v I reverse
• Unidirectional
|
| 20¢ each
- 18¢ (50+), 15¢ (500+) |
| |
|
30v - 500v Peak |
(RMO) SA30A
• 35.050v
@ 1ma V reverse standoff
• ± 1.75v tolerance
• 1µa @ 30v I reverse
• Unidirectional
|
| 20¢ each - 18¢ (50+),
15¢ (500+) |
| |
|
40v - 500v Peak |
(RMO) SA40A
• 46.750v
@ 1ma V reverse standoff
• ± 2.35v tolerance
• 1µa @ 40v I reverse
• Unidirectional
|
|
|
Transient Eliminator
250 MHz - 1 GHz |
 |
(RMO) TE-50N/SMA
250 MHz - 1 GHz transient spike eliminator will arrest 5000 amp surges, 500 joules,
on the coax cable leading to any low power transmitter, CCTV system, RF and
digital circuits of any kind, and computer data lines, in less than 5 nanoseconds
response time.
"N" connector input, "SMA" output. Great
for amateur of commercial service. |
| $65 each |
| |
|
|
5 amp Current Limiter |
 |
(RMO) CL-60
Keystone NTC inrush current limiter is a disc
type thermistor that controls initial surge at turn on for several seconds. 5 amp continuous,
10 ohm. |
|
| 20¢ each
- 18¢ (50+), 15¢ (500+) |
|
|
|
|
|
|
|
Air Gap
350v - 600v |
 |
(RMO) WP438
Multiple hit spark gap arrestor arcs from 350 - 600v. 3/8
- 24 threaded base. Cap removes to inspect element.
1/2" x 1-3/8" maximum dimension. |
|
|
3400 Joules
100 vdc - 71 vac
|
 |
(RMO) 9RV3A369
Made to absorb transients caused when an inductive field collapses, like in a
motor, which is by nature, high IMP. When the voltage goes up, the suppressor
goes to short. Made for 100 vdc or 71 vac. Install parallel with motor winding. |
|
| |
|
|
Self-Healing EMI Suppressor
Metalized Paper |
 |
(CFP) 004700KAFH
Revox Rifa self-healing EMI suppressor, metalized paper. 4,700 pF capacitor, 4n7, 20%, 440 / 250 vac, 115ºC. 4 kv for 60 seconds. 40 / 115 / 56 / B. 11/16"W x 11/16"H x 5/16"D. 5/8" lead spacing. |
| $2.50 each - $2 (10+) |
|
| |
|
|
SNC Induction
Neutralizing Transformer |
 |
(TEL) TLC-6
SNC's INT provides the highest possible conditioning of your data / telephone
lines by removing AC induction, noise and surges instantly! These units are
very expensive and priced here to sell... at a fraction of their original cost.
6 line unit. |
| $449 each |
| |
|
(TEL) TLC-12
12 line unit. |
|
| |
| |
SSL
|